Oil distribution transformers 50 kVA up to 2.500 kVA (2024)

Oil distribution transformers 50 kVA up to 2.500 kVA (9)
Oil distribution transformers 50 kVA up to 2.500 kVA (10)
<!–-TYPO3SEARCH_begin-–>

More than 70 years of know-how and experience is reflected in the oil distribution transformers made by SGB-SMIT Group.Our production (in Germany and Malaysia) is based on high-quality production materials, and we place the highest emphasis on first-class workmanship. The result: oil distribution transformers of maximum reliability!

Products and Services

For our durable oil distribution transformers we use only high-grade production materials and attach very great importance to sound workmanship, because the higher the material processing quality, the lower the running costs. These principles are incorporated into the following products:

  • Oil distribution transformers from 50 to 3,150 kVA
  • Large oil distribution transformers up to 20 MVA
  • Pole mounted transformers
  • Transformers for heating of track-switches or for pre-heating of trains
  • Neutral grounding transformers
  • Earthing transformers
  • Arc suppression coils
  • Transformers for special rectifier operation

We would above all like to point out that the use of special cooling/insulation material (e.g. Midel) is possible to enable operations at sites with special requirements regarding environment and fire protection.As a proven expert we furthermore offer a complex Transformer Logistics Package from a single source.

Components and systems for neutral-point connection

Medium-voltage systems in Europe are largely operated as resonant-earthed systems. SBG offers a complete range of products for the necessary neutral-point connection:

  • Arc suppression coils
  • Fixed coils as well as coils variable under load. The variable coils can be operated with the fitted electronic regulators and have an automatic mode.
  • Neutral electromagnetic couplers
  • Earthing transformers
  • Earth fault combinations consisting of neutral electromagnetic couplers and arc suppression coils.

In special cases the use of oil-immersed equipment is restricted due to environmental protection considerations. In these cases we use special synthetic or organic esters (e.g. Midel 7131).

Product Selection

Sächsisch-Bayerische STARKSTROM-GERÄTEBAU GMBH D-Regensburg

Technical Information Details

Details

Iron Core

Cold-rolled grain-oriented sheets in "Step-lap" laminationreduce no-load losses and no-load currents as well as noise emission.

Low Voltage Foil Winding

  • axial current distribution adjusts freely
  • reduces shearing forces

After winding, the Prepreg is stuck over the conductor sheet to form a compact tube by a tempering process.

High Voltage Winding

  • fully and semi-automatic winding machines
  • enamel-insulated winding wire with steady winding pull on carrier cylinder, or directly on the LV winding
  • layer insulation of high-quality cable paper
  • covering bandage made of shrinking foil for compact winding with good short-circuit response and optimum impulse voltage distribution

Assembly of active parts and vacuum drying

  • short-circuit proof assembly with profile steel and
  • support of coils
  • secure fixation of the electrical connections
  • The active part is securely joined to the cover and supported against the bottom of the tank.

  • low frequency or solvent vapour drying
  • filling of dried and degassed mineral oil

Tank

  • corrugated tank up to 10 MVA manufactured in-house
  • modern folding facility processes the steel sheet into high-quality corrugated walls
  • after the tank has been robot-welded, it is checked for leakage with control liquid and ultraviolet light.

Cover

The cover is made of doubling-free high-quality steel. It is bolted to the tank, and can also be welded to the tank on request. Besides bushings and lifting lugs the required control and monitoring devices are located on the cover.

Corrosion protection

  • Coating of tank and cover based on hydro-coating material by flooding or dipping method. (Standard RAL 7033)
  • On request the tank can also be manufactured in a hot-dip galvanised design.

Quality Test

Routine tests acc to din dve 0532

  • test with applied voltage (winding test)
  • test with induced voltage (turn test)
  • measurement of winding resistance
  • measurement of voltage ratio and determination of vector group
  • measurement of short-circuit voltage and of short-circuit losses
  • measurement of no-load current and of no-load losses

type and special tests acc to din vde 0532

  • temperature rise test
  • impulse voltage test
  • measurement of sound/noise level
  • partial discharge measurement

short-circuit strength

This test is performed within the scope of type tests, however, it can also be carried out in well-known and reputable test laboratories on request. After long-standing testing practice as well as positive experience on the part of our clients, the use of a cylinder block stuck to LV windings in combination with the HV layer windings has proved to be problem-free.

Reducing the noise emitted by the transformer in the environment is becoming more and more important. Therefore our oil distribution transformers also offer – besides the standard design acc. to DIN 42500 – reduced losses and noise levels too. In addition to the choice of flux density and core material, the step-lap technique of joining the legs and yoke also reduces noise levels and no-load losses in SGB transformers.

Downloads

BROCHURES

Distribution Transformers (1.7 MB, PDF)

Verteilertransformatoren(1.7 MB, PDF)

Transformateurs de distribution (1.7 MB, PDF)

OPERATION MANUALS

Operating Instruction B2021 DT (288 KB, PDF)

Bedienungsanleitung B2021 VT (290 KB, PDF)

NÁVOD K OBSLUZE B/2021 DT (290 KB, PDF)

Bedieningshandleiding B/2021 DT (288 KB, PDF)

Manuel d'utilisation B/2021 DT (290 KB, PDF)

Manual de instrucciones B/2021 DT (290 KB, PDF)

Instrucoes de utilizacao B/2021 DT (290 KB, PDF)

Insctrukcja obslugi B/2021 DT (288 KB, PDF)

References

Power Generation

Liquid filled Transformers within special Low-Loss-Design for renewable applications increase the efficiency of plants.

Oil distribution transformers 50 kVA up to 2.500 kVA (17)
Oil distribution transformers 50 kVA up to 2.500 kVA (18)

Power Distribution

Reliability of Distribution Transformers for all kinds of Power Distribution purposes support the productivity of our customers. Therefore, our Distribution Transformers comply with the highest standards in design and manufacuring.

Oil distribution transformers 50 kVA up to 2.500 kVA (19)

Industry

Reliability of Distribution Transformers for all kinds of Industrial purposes support the productivity of our customers. Therefore, our Distribution Transformers comply with the highest standards in design and manufacuring and meets special customer requirements.

Oil distribution transformers 50 kVA up to 2.500 kVA (20)
Oil distribution transformers 50 kVA up to 2.500 kVA (21)
Oil distribution transformers 50 kVA up to 2.500 kVA (22)
Oil distribution transformers 50 kVA up to 2.500 kVA (23)
Oil distribution transformers 50 kVA up to 2.500 kVA (24)
Oil distribution transformers 50 kVA up to 2.500 kVA (25)

Railways

Reliability of Distribution Transformers for all kinds of Power Distribution purposes support the productivity of our customers. Therefore, our Distribution Transformers comply with the highest standards in design and manufacuring.

Oil distribution transformers 50 kVA up to 2.500 kVA (26)
Oil distribution transformers 50 kVA up to 2.500 kVA (27)
Oil distribution transformers 50 kVA up to 2.500 kVA (28)

Infrastructure

Reliability of Distribution Transformers for all kinds of Power Distribution purposes support the productivity of our customers. Therefore, our Distribution Transformers comply with the highest standards in design and manufacuring.

Oil distribution transformers 50 kVA up to 2.500 kVA (29)
Oil distribution transformers 50 kVA up to 2.500 kVA (30)
Oil distribution transformers 50 kVA up to 2.500 kVA (31)
Oil distribution transformers 50 kVA up to 2.500 kVA (32)
Oil distribution transformers 50 kVA up to 2.500 kVA (33)
Oil distribution transformers 50 kVA up to 2.500 kVA (34)
Oil distribution transformers 50 kVA up to 2.500 kVA (35)

Contact Person

<!–-TYPO3SEARCH_end-–>
About Cookies

This website uses cookies. Those have two functions: On the one hand they are providing basic functionality for this website. On the other hand they allow us to improve our content for you by saving and analyzing anonymized user data. You can redraw your consent to using these cookies at any time. Find more information regarding cookies on our Data Protection Declaration and regarding us on the Legal notice.

Oil distribution transformers 50 kVA up to 2.500 kVA (2024)

FAQs

How much load can a 50 kVA transformer handle? ›

A 50 kVA transformer can handle around 120.28 amperes at 240 volts 3-phase. To calculate that value, we: First convert 50 kVA to 50,000 VA by multiplying 50 kVA by 1,000. Then divide 50,000 VA by 240 volts to get 208.333 amperes.

How much oil does a 2500 kVA transformer hold? ›

How much oil is in a 2500 kVA transformer? The transformer oil of a 2500 kVA, 13.8kv pad-mounted transformer is 383 Gal.

What does 50 kVA mean in transformer? ›

What is a 50 kVA transformer? A 50 kVA transformer has a capacity of 50 kilovolt-amperes, with a power factor of approximately 0.85. It provides around 45 kW of active power and can support electrical appliances consuming up to 45 kW.

What cooling system is used for distribution transformers up to 2500 kVA? ›

ONAN/ONAF (KNAN/KNAF) Extended Cooling Class Ratings

For example, a transformer may be rated ONAN/ONAF (2500/3125 kVA). Up to 2500 kVA, the transformer's cooling surface (tank and radiators) is air cooled by natural convection. Above 2500 kVA, the transformer's fans activate.

What is the full load current of a 50 kVA transformer? ›

Amperage provided for a given KVA can be determined by similar techniques: Single Phase Example: Using a 50 KVA Single Phase Transformer as a starting point. 50KVA is equal to 50,000 VA. (K= 1,000) The full value in VA, 50,000 is then divided by the Voltage 240V = 208 Amperes.

How many houses can a 50 kVA transformer supply? ›

But for 240VAC 200A service, that's 48kVA, so a 50 kVA transformer can power only one home. However, at 1500 KWH/month or 50 KWH/day or 2.083 KWH/hour or average 2.083 kVA. But that's the average. I would say it could be up to 5 times or 10kVA at a time, so a 50kVA transformer can power 5 homes.

How to calculate transformer oil capacity? ›

To determine the capacity of oil immersed transformer, the load rate of oil immersed transformer must be determined first. When the air vibration loss is equal to the square of load rate and load loss, the efficiency of oil immersed transformer is higher.

How much oil required for 2.8 kVA generator? ›

SPECIFICATIONS
Air CleanerDual type
Noise Level86 dB
Oil Capacity0.55 L
Spark PlugBPR6ES (NGK)
Starting SystemRecoil or electric starter
18 more rows

What is the oil capacity of 315 kVA transformer? ›

The oil capacity of a 315KVA transformer is 380 liters.

According to the requirements of the environment, Daelim can offer vegetable oil with UL certification. Liters of oil advisable for 315 kVA transformer (not including oil absorbed by the core and coil assembly): Voltage rating of 11/0.433 kV = 500.

How to calculate transformer load capacity? ›

kVA= Current × Voltage × √3 / 1000

Say your household load voltage is 2000V, and the load current is 250A. For this load capacity, the suggested size of the transformer is 1000kVA.

What happens if load on transformer is reduced by 50? ›

Below 50% load, the following effects may be noticed: (1) Regulation will improve. This means slightly increased secondary terminal voltage. (2) Depending upon the ratio copper loss to core loss, efficiency may decrease or increase.

How much is a 50KVA transformer? ›

Transformer - Price Range
TransformersMin price(₦)Max price
ABB Power Transformer 50KVA5,650,000.005,800,000.00
ABB Power Transformer 100KVA6,250,000.006,550,000.00
ABB Power Transformer 200KVA7,000,000.007,500,000.00
ABB Power Transformer 300KVA8,900,000.009,700,000.00
1 more row

How much load can a 2500 kVA transformer handle? ›

If a transformer rated for 2500 VA is loaded resistively, it can handle a power input/output of 2.5 kw.

Why do transformers need to be cooled? ›

Cooling of a transformer is the process of dissipation of heat developed in the transformer to the surroundings. The losses occurring in the transformer are converted into heat which increases the temperature of the windings and the core. Therefore, cooling is done to dissipate the heat generated in the transformer.

Which transformer is the commonly used in residential distribution system? ›

It can step down the high voltage (7.2kV, 14.4kV, 12.47kV, 24.94kV) to the low voltage (120V, 240V) required by household electrical equipment. Types of Residential Transformers: The most common types of residential transformers are pole-mounted and pad-mounted transformers.

What is the maximum load capacity of a transformer? ›

1, if it is a power transformer, for example, the high voltage is 35kV, and the low voltage is 3.15-11kV. So, whether load voltage regulation or no excitation voltage regulation, according to the national standard, the maximum capacity is 20000kVA.

What size breaker do I need for a 50 kVA transformer? ›

Ok in that case you will need to use a 50amp 480v breaker to protect the transformer/feed power to it.

What is the inrush current of a 50kVA transformer? ›

A 50kVA transformer may have an inrush current of between 8 and 10 times its FLA, for a maximum time of 0.1s.

How do you calculate power handling capacity of a transformer? ›

To calculate the kVA rating for a single-phase transformer, you'll need to multiply the required input voltage (V) by the required current load in amperes (l) and then divide that number by 1,000: V * l / 1,000.

Top Articles
Latest Posts
Article information

Author: Laurine Ryan

Last Updated:

Views: 5404

Rating: 4.7 / 5 (57 voted)

Reviews: 80% of readers found this page helpful

Author information

Name: Laurine Ryan

Birthday: 1994-12-23

Address: Suite 751 871 Lissette Throughway, West Kittie, NH 41603

Phone: +2366831109631

Job: Sales Producer

Hobby: Creative writing, Motor sports, Do it yourself, Skateboarding, Coffee roasting, Calligraphy, Stand-up comedy

Introduction: My name is Laurine Ryan, I am a adorable, fair, graceful, spotless, gorgeous, homely, cooperative person who loves writing and wants to share my knowledge and understanding with you.